Adhiam

Author name: admin

Plate Heat Exchanger Manufacturers In Chennai

A plate heat exchanger consists of corrugated plates fixed with gasket and these are mounted between fixed frame and movable frame, Top and Bottom carrying bar are used for hanging the plates in-between frames and ties rods are used for tightening to the required plate pack. Fluids enter through the connections in the frame and are distributed in between plates. The fluids flow thorough alternate passages between plates by means of gasket arrangement. Plate Heat Exchanger Manufacturers In Tamil Nadu.

Plate Heat Exchanger Manufacturers In Chennai Read More »

Solar PV power plant

100kW Ground Mounting On Grid Solar Power Plant In Chemical Plant Near Chennai

Most of the big companies have realized that going green not only for their corporate social responsibility , but also for reducing the over  all cost of energy. The companies  are also eager to reduce their carbon footprint . Solar energy represents Clean, Green Source of energy.  This does not release greenhouse gasses , and except for the needing a source of clean water to function, it uses absolutely no other resources. Safe and environmentally friendly. We got an opportunity to become part of the green energy project and installed ” 100KW Ground Mounting On Grid Solar power plant in chemical plant near Chennai ” 100KW Solar PV power plant produces 390 units per day and this being chemical factory paying the commercial tariff rate of Rs 7 to 8 per Unit, the saving per year is approximately Rs 8,20,000 per year. The payback is less than 5 years.

100kW Ground Mounting On Grid Solar Power Plant In Chemical Plant Near Chennai Read More »

Chemical Cleaning Of Mobilizers In Edible Oil Plants

Adhiam with its CIP system cleans most of the Heat Exchangers apart from the Plate heat exchangers as per the request of our customer. One such requirement has come to us for CIP cleaning of the Mobilizers in the Edible Oil plants. We could do the chemical cleaning to various Edible oil plants in Krishnapatinam Industrial area, Telugana State. The coil inside the tank is almost choked and the heat transfer is not effectively happening in the tank and hence the production time is increased. After the chemical cleaning of the coil, the performance is increased to 80% and the time required is reduced drastically . It is recommended by the Plant Personnel to do the cleaning of the coil once in 6 months to reduce the scale and hence to increase the heat transfer efficiency. Three of edible oil customers have given AMC contract for the same. As Adhiam is having experienced technicians and engineers for chemical cleaning of heat exchangers and the process for CIP remain similar to the Heat Exchanger , but here  the number of hours circulation is more due to heavy scales in the coil .

Chemical Cleaning Of Mobilizers In Edible Oil Plants Read More »

Scroll to Top